SIVERS Waveguide Switch WS8089D6/00
See full specification tab below or
At a glance: Key parameters
RF DATA
Frequency range: 6.5 – 18.0 GHz
VSWR 1.2
Insertion loss: 0.4 dB
Isolation: 50 dB
Peak power: 20 kW at 0.1 MPa abs., +25°C
Average power: 500 W
Flange interface (see page 2)
ACTUATOR DATA
Operating voltage: 28±3 VDC
Operating current: 1 A, self-cut off
Switching time: 150 ms
Duty (min time between 500 ms -40°C and +40°C)
successive operations) linearly increasing to 2 s at +85°C
Connector Soldering pins
POSITION INDICATOR
Position indicator current: 60 V Max, 50 mA Max Resistive load
MECHANICAL DATA
Material: aluminum alloy, Cu-free
Finishing the chronometer per MIL-C-5541 and black painting
Air pressure: 0.1 MPa; overpressure: Max
Air leakage: 10 cm3
/min. (0.1 MPa overpressure) Max
Weight: 0.35 kg Max
Life: 250 000 actuations
ENVIRONMENTAL DATA
Ambient temperature: -40°C to +85°C
Vibration: 5 – 18 Hz, 3 mm amplitude
18 – 2000 Hz, 15 g
Humidity: 100% RH if dry air is in waveguide